Accuracy
- Up to ± 0.1 % Pressure Non-Linearity
Ambient Temperature Range
Applications
- Fresh & Waste Water Measurements
- Medical Equipment
- Partial Vacuum Gas Measurement
- Pressure Transmitters
- Process Control
- Tank Level Systems (RV & Industrial)
Approvals & Certifications
Compensated Temperature
- -20° to 85° C (-4° to 185° F)
Hysteresis
- ± 0.05 % of Span - Pressure Hysteresis
- ± 0.25 % of Span - Thermal Hysteresis: Span & Offset
Load Impedance
- 5 megaohms - Output Load Resistance
Operating Temperature - Sensor
- -40° to 125° C (-40° to 257° F)
Output
- ± 1 mV - Zero Pressure Output
- 70 to 150 mV - Span Value
Output Noise
- 1 µV Peak-to-Peak - Output Noise (10 Hz to 1 kHz)
Pressure Range
- psiv: 0 to 500 (kPa: 0 to 3,447, bar: 0 to 34.47)
Resistance
- 2,000 to 5,800 ohms - Input Resistance
- 4,000 to 6,000 ohms - Output Resistance
Response Time
- 0.1 millisecond - Response Time (10 to 90 %)
Sensor, Probe Diameter
- 0.74” (19 mm) - Diameter Package
Span - Minimum
- 1 % - Interchangeable Span
Stability
- ± 0.10 % of Span/Year - Long Term Stability: Span & Offset
Storage Temperature
- -50° to 125° C (-58° to 257° F)
Temperature Effect
- ± 0.75 % of Span - Temperature Error - Span & Offset