Approvals & Certifications
Compensated Temperature
- -20° to 85° C (-4° to 185° F)
Electrical Protection
- Over Voltage Protection - 16 V
Loop Resistance
- 10 kiloohms - Load Resistance
Operating Temperature
- -40° to 125° C (-40° to 257° F)
Pressure Range
- bar: 0 to 10.3
- kPa: 0 to 1,034
- psi: 0 to 150
Reverse Polarity Protection
Shock
- Half-Sine, Peak: 50 G, 11 ms MIL-STD-202, Method 213B, Condition A
Stability
- ± 0.25 % of Span/Year - Long Term Stability
Storage Temperature
- -40° to 125° C (-40° to 250° F)
Vibration