XFTC302 Miniature Load Cell
Brand: American Sensor Technologies IncXFTC302 Miniature Load Cell
Brand: American Sensor Technologies IncThe XFTC302 series has been specifically developed to measure tension and/or compression in static and dynamic applications.
Fitted with metallic strain gauges in a Wheatstone bridge circuit, the XFTC302 has the capacity of measuring heavy loads of up to 10,000 N, 2000 lbf while providing excellent temperature stability. With two threaded M10 studs, the XFTC302 is easily installed in industrial or OEM applications. A strain relief spring strengthens the cable output.
Features- Wide Temperature Compensation Range
- Optional IP Rating Improvement
- Heavy Duty
- Integrated Amplifier Optional
- Easy to Customized Signal and Design
Specifications
Approvals & Certifications
- CE
Compensated Temperature
- 0° to 150° C (32° to 302° F) - without Electronic
- 0° to 85° C (32° to 185° F) - with A1 Option
Consumption
- < 30 mA
Electrical Connectors
- Shielded Cable with 4-Wires (AWG 28)
Enclosure, Body Material
- Stainless Steel
Environmental Protection
- IP50
Hysteresis
- ≤ ± 0.5 % of Full Scale
Input Impedance
- 700 ohms
Insulation Resistance
- ≥ 1,000 megaohms at 50 Vdc
- ≥ 100 megaohms at 50 Vdc
Linearization
- ≤ ± 0.5 % of Full Scale
Operating Temperature
- -40° to 85° C (-40° to 185° F) - with A1 Option
- -55° to 175° C (-67° to 347° F) - without Electronic
Resistance
- 500 to 1,000 ohms - Output Impedance
Sensitivity
- < 1 % of Reading / 50° C (100° F) - Thermal Sensitivity Shift
- ± 1 mV/V of Full Scale Output
- ± 2 V ± 0.2 V of Full Scale Output
Supply Voltage
- 10 Vdc
- 10-30 Vdc
Thermal Drift
- < 1 % of Full Scale / 50° C (100° F) - Thermal Zero Shift in CTR
UNF/UNC Connection
- 3/8”-24 UNF Male
Zero Offset
- < ± 5 % of Full Scale
- 2.5 V ± 0.2 V
- Dynamic Strain Cylinder Regulation
- Miniature Force & Temperature Tests
- Motor Sport Clutch Monitoring
- Robotics Regulation
- Heat Room Environment