FP110 Heavy Industrial Pressure Transducer
Brand: American Sensor Technologies IncFP110 Heavy Industrial Pressure Transducer
Brand: American Sensor Technologies IncThe FP110 is designed to measure static and dynamic pressure with the output characteristics substantially kept up to about 20% of the resonant frequency.
The all stainless steel construction and flush diaphragm allow the sensor to be used under a wide variety of conditions and in temperatures up to 120°C. For 200°C high temperature range model FP120-/HT.
Fitted with metallic strain gauges in a Wheatstone bridge circuit, the FP110 provides excellent temperature stability. An onboard A1 or A2 amplifier for high level output is optionally available.
Features- Built in stainless Steel
- M16 thread
- High Level Tension Output Available
- Accepts wide range of fluids
Specifications
Accuracy
- < ± 0.3 % of Full Scale
- < ± 0.5 % of Full Scale
Applications
- Corrosive Fluid Storage
- Hydraulic Regulation Process
- Industrial Pump Discharge
- Laboratory & Research
- On-Board Equipment Monitoring
Approvals & Certifications
- CE
- EN 50 082-1
- EN 50081-1
- EN 61010-1
Compensated Temperature
- 0° to 60° C (32° to 140° F)
Diaphragm Material
- Flush
- Stainless Steel
Environmental Protection
- IP66
Frequency
- 15 to 55 kHz - Resonance Frequency
Hysteresis
- ± 0.05 % of Span
Input Impedance
- < 25 mA - FP110-A1, FP110-A2
- 350 ohms - FP110
Insulation Resistance
- ≥ 100 megaohms at 50 Vdc
Linearization
- ± 0.3 % of Full Scale - Non-Linearity
Materials of Construction
- 316 Stainless Steel
Operating Temperature
- -40° to 80° C (-40° to 176° F)
Output
- 1.2 mV/V - FP110
- 4 V ± 0.2 V - FP110-A1
- 5 V ± 0.2 V - FP110-A2
Pressure Range
- bar: 10 to 500
- kPa: 1,000 to 50,000
- psi: 150 to 7,500
Pressure Type
- Gauge
Sensitivity
- < 1.5 % of Reading / 50° C (100° F) - Thermal Sensitivity Shift
Sensor, Probe Connection
- 4-Wire
Supply Voltage
- ± 15 Vdc (± 12 to ± 18 Vdc) - FP110-A2
- 10 Vdc - FP110
- 10-30 Vdc - FP110-A1
Thermal Drift
- < 1 % of Full Scale / 50° C (100° F) - Thermal Zero Shift
Thread
- M16
Wiring
- Shielded Cable
Zero Offset
- < ± 5 % of Full Scale - FP110
- 0 V ± 0.2 V - FP110-A2
- 0.5 V ± 0.2 V - FP110-A1
- Industrial Pump Discharge
- Corrosive Fluid Storage
- Onboard Equipment Monitoring
- Hydraulic Regulation Process
- Laboratory and Research