Axiom AMI Series Valve Position Monitor
Brand: ValmetAxiom AMI Series Valve Position Monitor
Brand: ValmetThe Axiom AMI integrates solid state continuous sensing and pneumatic control to give long life and reliable performance in process applications.
The AMI also features the capability for intermediate valve control and diagnostics to offer more cost saving benefits.
Features- The Axiom is corrosion proof, temporarily submersible and suitable for use in hazardous areas. Designed for NEMA 4, 4X & 6; (IP67) Class I & II Div 2 nonincendive (Ex nA, Zone 2) and Class I & II Div 1 & 2 (Ex ia, Zones 0, 1, & 2) Intrinsically Safe
- Universal Voltage Solenoid System operates on less than 0.6 watts of power and is burn out proof. Standard version will accept 24 Vdc, 120 Vac or 240 Vac, reducing stocking requirements
- Standard 5-way, 2-position valve operates both double and single-acting actuators and features a rebreather to feed instrument air into spring side of actuator to keep out corrosives
- High accuracy position sensor system is solid state with no moving wear points for highly reliable and precise position feedback
- Integral pneumatic valve operates on standard plant air and will cycle most actuators in less than two seconds
Specifications
Brand
Accuracy
- Expeditor Intermediate Control Accuracy: ± 3° of Rotation
- Expeditor Positioning Monitoring Accuracy: ± 1° of Rotation
- HART with Diagnostics Pressure Accuracy: ± 1 % of Full Scale
- Position Sensor System Accuracy: within 1°
Actuator Type
- Double-Acting
- Single-Acting
Approvals & Certifications
- ATEX II 1 G Ex ia IIC T5
- CE 1725
- FCC
- FM Intrinsically Safe (AMI93 - FISCO) Class I, II, III, Div. 1, Grade A, B, C, D, E, F, G
- FM Non-Incendive Apparatus Class I, Div. 2, Grade A, B, C, D & Class II, Div. 2, Groups F, G
- IC
- IEC 61508 Parts 1-7: 2010 & IEC 61511-1: 2003 + Corr. 1: 2004
- IEC 61508 Parts 1-7: 2010 & IEC 61511-1: 2003+Corr. 1: 2004
- TR CU 0Ex ia IIC T5 Ga X
Cap Material
- Pneumatic Valve End-Caps & Fasteners: Stainless Steel
Communication
- AS-Interface
- DeviceNET Protocol
- FOUNDATION Fieldbus
- HART
Conduit Connection
- 1/2” NPT
- M20
- Micro Connector
- Mini Connector
Configuration
- 2-Wire Solid State Switches
- Auxiliary Discrete Input
- Discrete Position Sensor Input
- Discrete Sensor Input
- Dual Pilot
- Low Air Supply Pressure Input
- Modified Output Block
- Multiple DI/DO Blocks
- Parameter Bit Spring
- Peripheral Fault Bit
- Remote Sensor Setting
- Single Pilot
- Solenoid Power Input
- Stuck Valve/Actuator Input
- Wink Feature
Current
- HART with Diagnostics Current Output (Position Feedback): 4-20 mA
- NAMUR Sensor 44 Current Rating: Target Off > 2.1 mA
- NAMUR Sensor 44 Current Rating: Target on < 1.0 mA
- Stainless Steel Sensor 33 & 35 Min. on Current: 2.0 mA
- Stainless Steel Sensor 33 & 35, Max.
- VCT with Diagnostics, Max.
- VCT with Extended Addressing, Max.
- VCT with Wireless Link, Max.
- VCT, Max.
Deadband
- 6° from Set Point - Rotational Distance from Original Set Point where Switch Will De-Energize
Display
- LEDs
Electrical Rating
- Pneumatic Valve _A Option Electrical Rating: 2 mA at 6.5 Vdc
- Pneumatic Valve _D & _E Option Electrical Rating: 0.5 W at 12 Vdc (Intrinsically Safe)
- Pneumatic Valve _H Option Electrical Rating: 0.6 W at 22-250 Vac/Vdc
Enclosure, Body Material
- Epoxy Coated Anodized Aluminum
Environmental Protection
- IP67
- NEMA 4
- NEMA 4X
- NEMA 6
Filter
- Piezo Pilot Filtration Requirement: Dried / 30 microns
- Pneumatic Valve Filtration Requirement: 40 microns
Indication
- Red/Green
Input
- 2 mA
- 24 Vdc at 2 mA
- Expeditor Position Feedback Control (Analog Input): 9-35 Vdc
- Stainless Steel Sensor 33 Solenoid Input: 22-130 Vac/Vdc
- Stainless Steel Sensor 35 Solenoid Input: 20-250 Vac
- Stainless Steel Sensor 35 Solenoid Input: 20-60 Vdc
Materials of Construction
- Fasteners & Mounting Adaptors: 316 Stainless Steel
- Pneumatic Valve Spool: Nickel-Plated Aluminum
- Visual Indicator: Lexan Polycarbonate
O-Ring Material
- Nitrile
Operating Pressure
- psi: 40 to 120 (kPa: 275.8 to 827.4, bar: 2.8 to 8.3)
Operating Temperature
- Piezo Pilot Operating Temperature: -10° to 60° C (14° to 140° F)
- Pneumatic Valve Extended Operating Temperature: -40° to 80° C (-40° to 176° F)
- Solenoid Pilot & Pneumatic Valve Standard Operating Temperature: -18° to 50° C (0° to 122° F)
Operation
- NAMUR Sensor 44 Operation: Normally Closed NAMUR Sensors (Solid State)
- Pneumatic Valve Pilot Operator Option: Piezo
- Pneumatic Valve Pilot Operator Option: Solenoid Coil
- Stainless Steel Sensor 33 & 35 Operation: Normally Open (Solid State)
Output
- 2 mA
- 4 W
- DeviceNet Output: 4 W at 24 Vdc Both Outputs Combined
- DeviceNet Outputs, Voltage: 24 Vdc
- Expeditor Intermediate Position Control (Analog Output): 4-20 mA Loop
- VCT FOUNDATION Fieldbus Output: 2 mA at 6.5 Vdc Each, Current Limited to 2 mA (Bus Powered)
- VCT Outputs: 4 W at 24 Vdc Both Outputs Combined
- VCT with Diagnostics Outputs: 0.5 W at 24 Vdc
- VCT with Extended Addressing Option, Voltage: 21-26 Vdc
- VCT with Extended Addressing Output: 2 W at 24 Vdc
- VCT with Wireless Link Output, Voltage: 24 Vdc (± 10 %)
- VCT with Wireless Link Output: 4 W at 24 Vdc
Port
- Pneumatic Valve Axiom & Manifold Porting: 1/4” NPT
Power
- 0.5 W
- Expeditor Solenoid Power: 0.5 W (0.02 A at 24 Vdc)
- Expeditor Solenoid Power: 0.5 W Intrinsically Safe (0.04 A at 12 Vdc)
- HART with Diagnostics Solenoid Power (Conventional): 0.5 W (0.02 A at 24 Vdc)
- HART with Diagnostics Solenoid Power (Intrinsic Safety): 0.5 W (0.04 A at 12 Vdc)
Rating
- Pneumatic Valve Flow Rating: 0.70 CV
Repeatability
- Position Sensor System Repeatability: within 1°
Rotation
- Position Sensor System, Max.
Seat / Seal Material
- Nitrile
- Pneumatic Valve Seal Spacers: Polysulfone
Set Point Range
- 4° from Set Point - Rotational Distance from Original Set Point where Switch Will Energize on Return Stroke
Supply Pressure
- psi: 40 to 120 (kPa: 275.8 to 827.4, bar: 2.7 to 8.2)
Temperature Range
- Expeditor Temperature Rating (Extended): -20° to 80° C (-4° to 176° F)
- Expeditor Temperature Rating (Standard): -18° to 50° C (0° to 122° F)
Voltage
- Expeditor Solenoid Voltage (Conventional Models): 24 Vdc
- Expeditor Solenoid Voltage (Intrinsic Safety Models): 12 Vdc
- HART with Diagnostics Loop Resistance (Position Feedback): 250 ohms (Min) to 400 ohms, Max.
- HART with Diagnostics Voltage (Position Feedback): 14-35 Vdc (24 Vdc Nominal)
- NAMUR Sensor 44 Voltage Range: 7-24 Vdc
- Stainless Steel Sensor 33 Voltage Range: 125 Vdc
- Stainless Steel Sensor 33 Voltage Range: 20-125 Vac
- Stainless Steel Sensor 35 Voltage Range: 20-250 Vac
- Stainless Steel Sensor 35 Voltage Range: 8-250 Vdc
- VCT Outputs, Voltage: 21-26 Vdc
- VCT with Diagnostics Outputs, Voltage: 24 Vdc
- VCT with Output, Voltage: 21-26 Vdc
Voltage Drop
- Stainless Steel Sensor 33, Max.
- Stainless Steel Sensor 35, Max.
Documentation
Certifications & Approvals
- StoneL Axiom AMI Series Valve Position Monitor - ATEX Certificate 1 pdf 387 KB
- StoneL Axiom AMI Series Valve Position Monitor - ATEX Certificate 2 pdf 929 KB
- StoneL Axiom AMI Series Valve Position Monitor - CU-TR Certificate pdf 3.7 MB
- StoneL Axiom AMI Series Valve Position Monitor - FM Certficiate 1 pdf 173 KB
- StoneL Axiom AMI Series Valve Position Monitor - FM Certificate 2 pdf 173 KB
- StoneL Axiom AMI Series Valve Position Monitor - SIL Certificate pdf 702 KB