MS8607-02BA01-Digital Pressure & Altimeter
Brand: American Sensor Technologies IncMS8607-02BA01-Digital Pressure & Altimeter
Brand: American Sensor Technologies IncThe MS8607 is the novel digital combination sensor of MEAS providing 3 environmental physical measurements all-in-one: pressure, humidity and temperature (PHT).
This product is optimal for applications in which key requirements such as ultra low power consumption, high PHT accuracy and compactness are critical. High pressure resolution combined with high PHT linearity makes the MS8607 an ideal candidate for environmental monitoring and altimeter in smart phones and tablet PC, as well as PHT applications such as HVAC and weather stations.
Specifications
Accuracy
- ± 50 mV - Low Battery Indicator Accuracy
Approvals & Certifications
- RoHS
Communication
- 16-bits - ADC Output Word for Relative Humidity
- 24-bits - ADC Output Word for Pressure & Temperature
Frequency
- 400 kHz - Serial Data Clock
Humidity
- 0 to 100 % Relative Humidity
Input
- 0.03-0.24 µA - Standby Supply Current at 25° C
- 0.45 mA - Peak Supply Current (Humidity)
- 0.63 - 20.09 µA - Supply Current (Pressure or Temperature)
- 0.78-6.22 µA - Supply Current (Humidity)
- 0-20 % Vdd - Input Low Voltage
- 1.25 mA - Peak Supply Current (Pressure or Temperature)
- 80-100 % Vdd - Input High Voltage
Load Limit
- 16 PF - Load Capacitance
- 220-470 NF - Vdd to Ground Capacitor
Maximum System Pressure
- psi: 87.02 (kPa: 600, bar: 6)
Operating Pressure
- psi: 0.145 to 29.01 (kPa: 1 to 200, Mbar: 10 to 2,000)
Operating Temperature
- -40° to 85° C (-40° to 185° F)
Operating Voltages
- 1.5-3.6 V - Operating Supply Voltage
Output
- ± 100 mA - Latch Up
- 0-20 % Vdd - Output Low Voltage
- 80-100 % Vdd - Output High Voltage
Response Time
- < 5 milliseconds for Pressure
- 0.54 to 17.2 milliseconds - ADC Conversion Time for Pressure & Temperature
- 1.84 to 15.89 milliseconds - ADC Conversion Time for Relative Humidity
- 5 seconds for Relative Humidity
Sensitivity
- ± 2 kV - ESD Rating
Stability
- ± 0.3° C (± 0.54° F)/Year - Long Term Stability for Temperature
- ± 0.5 % Per Year - Long Term Stability for Relative Humidity
- ± 1 Mbar Per Year - Long Term Stability for Pressure
Storage Temperature
- -20° to 85° C (-4° to 185° F)
Supply Voltage
- -0.3 to -3.6 V
- 1.5-3.6 V at ± 0.25 % - Max.
- 1.5-3.6 V at ± 0.3° C - Max.
- 1.5-3.6 V at ± 0.5 Mbar - Max.
Temperature Range
- 250° C (482° F) - Max.
- Smart phones and Tablet PCs
- HVAC Applications
- Weather Station
- Printers
- Home Appliance and Humidifiers