Accuracy
- ± 1° C (± 1.8° F)
- 0.2 % of Full Scale - Non-Linearity Typical
- 2 % of Full Scale - Non-Linearity, Max.
Frequency
- 0 to 10,000 Hz - Frequency Response
Input
- 15-20 mA - Input Current
- -20 to 38 V - Input Voltage Limits
- 8.5-36 V - Input Voltage - Operating
Materials of Construction
Output
- 0.5 - 4.5 V - Output Voltage Swing
Sensitivity
- ± 0.25 % - Transverse Sensitivity
- ± 4 mV/g at 25° C
- ± 8 mV/g at 25° C
- 6.45 mV/°C
Shock
- ± 4,000 G - Any Axis for 0.5 milliseconds, Powered or UnPowered
Temperature Range
- -40° to 85° C (-40° to 185° F)
Thermal Drift
- ± 1,000 mg at 1.25° cycles/min Rate of Change - Zero G Bias Level