Accuracy
- ± 0.5° C (± 0.9° F) Typical - Temperature Acuracy
- ± 1 % of Full Scale Typical - Pressure Accuracy
- ± 1.5 % of Full Scale, Max.
- ± 1.5° C (± 2.7° F) - Max.
- ± 3 % Relative Humidity Typical - Relative Humidity Accuracy (10 % to 95 % Relative Humidity)
- ± 5 % Relative Humidity, Max.
Approvals & Certifications
Burst Pressure
- psi: 18.85 (kPa: 130, bar: 1.3)
Current
- 150 mA - Sink Current Capability
- 15-100 mA at 12 V - Current Consumption
- 20-104 mA at 24 V - Current Consumption
Electromagnetic Rating
- EMC Directive
- ESD Protection
Humidity
- 0 to 100 % Relative Humidity
Hysteresis
- ± 1 % Relative Humidity - Humidity Hysteresis
Input
- 0.9-5 V - Differential Input Voltage (Dominant)
- -1 to 0.5 V - Differential Input Voltage (Recessive)
- 150 mV - Differential Input Hysteresis
Operating Temperature
- -40° to 105° C (-40° to 221° F)
Pressure Range
- bar: 0.01 to 2.5
- kPa: 0 to 250
- psi: 0.14 to 36.26
Resistance
- 20 to 100 kiloohms - Differential Input Resistance
- 5 to 25 kiloohms - CAN_H, CAN_L Input Resistance
Resolution
- ± 0.5 kPa - Pressure Resolution
- 0.4 % Relative Humidity - Relative Humidity Resolution
Response Time
- 1 second - Pressure Time Constant
- 10 seconds - Temperature Time Constant
- 5 to 10 seconds - Time Constant (At 63 % of Signal) 33 to 75 % Relative Humidity
Stability
- ± 0.3° C (± 0.54° F)/Year - Temperature Long Term Stability
- ± 0.5 kPa/Year - Pressure Long Term Stability
- ± 0.5 % Relative Humidity/Year - Long Term Stability
Storage Temperature
- -40° to 125° C (-40° to 257° F)
Supply Voltage
- -200 to 200 V - Transient Voltage on CAN_H & CAN_L
- 32 Vdc - Supply Voltage (Peak)
- -36 to 36 V - DC Voltage at CAN_L & CAN_H
- 8-32 Vdc at 23° C (73.4° F)
Temperature Range
- -40° to 105° C (-40° to 221° F)
Torque
- 106 In/Lbs - Typical Tightening Torque
- 150 In/Lbs - Max.