Ambient Temperature Range
Approvals & Certifications
Consumption
- 1.4 mA - Typical
- 2 mA - Typical
Humidity
- ± 2 % Relative Humidity - Typical Relative Humidity Accuracy
- ± 3 % Relative Humidity - Max.
- ± 5 % Relative Humidity - Relative Humidity Accuracy at 55 % Relative Humidity at 23° C
- 0 to 100 % Relative Humidity
Hysteresis
- ± 1 % Relative Humidity - Humidity Hysteresis
Operating Temperature
- -40° to 60° C (-40° to 140° F)
Resolution
- 0.4 % Relative Humidity - Humidity Resolution
Sensitivity
- 26 mV/ % Relative Humidity - Humidity Average Sensitivity from 5 % to 10 % Relative Humidity
Stability
- 0.5 % Relative Humidity/Year
Storage Temperature
- -30° to 70° C (-22° to 158° F)
Supply Voltage
- 10 Vdc
- 4.75-5.25 Vdc - Regulated at 5 Vdc
Temperature Effect
- -0.05 % Relative Humidity/°C
- -0.1 % Relative Humidity/°C