Ambient Temperature Range
Applications
- Corrosive Fluid Systems
- Flow Measurement
- Gas Measurement
- Industrial OEM Equipment
- Level Controls
- Tank Level Measurement
Approvals & Certifications
Burst Pressure
- 1 psi: 12X, Max.
- 5 psi: 4X, Max.
Compensated Temperature
- -20° to 85° C (-4° to 185° F)
Hysteresis
- ± 0.02 % of Span - Pressure
Materials of Construction
- 316 Stainless Steel - Port
Operating Temperature
- -40° to 125° C (-40° to 257° F)
Output Noise
- 1 µV Peak-to-Peak (10 Hz to 1 kHz)
Pressure Range
- psid: 0 to 500 (kPa: 0 to 3,447, bar: 0 to 34.47)
Resistance
- 2,000 to 5,800 ohms - Input
- 4,000 to 30,000 ohms - Output
Response Time
- 0.1 millisecond - Response Time (10 to 90 %)
Shock
- 50 G, 1 millisecond 1/2 Sine Per MIL-STD-202 G, Method 213B, Condition A
Stability
- ± 0.10 % of Span/Year - Span
- ± 0.25 % of Span/Year - Offset & Span
Storage Temperature
- -40° to 125° C (-40° to 257° F)