Accuracy
- ± 0.8° C (± 1.4° F)
- ± 1.5° C (34.7° F) at 10° to 40° C (50° to 104° F)
- ± 2.5 % Mbar at 10° to 40° C (50° to 104° F) - Pressure Accuracy
- ± 9 Mbar at 10° to 40° C (50° to 104° F) - Pressure Accuracy
Approvals & Certifications
Communication
- 16-bit - Analog to Digital Converter
Consumption
- 0.5 µA - Current Consumption Into MCLK
Differential Pressure
- psi: -72.52 to 72.52 (kPa: -500 to 500, bar: -5 to 5) - Differential Overpressure
Duty Cycle
- 40 to 60 % - Duty Cycle of MCLK
Frequency
- 30 to 500 KiloHertz - External & Serial Data Clock (MCLK & SCLK)
Input
- 0-20 % Vdd - Input & Output Low Voltage
- 80-100 % Vdd - Input & Output High Voltage
Operating Temperature
- -40° to 85° C (-40° to 185° F)
Output
- 0.1 µA - Max.
- 1 mA - Typical Supply Current (During Conversion)
- 4 µA - Typical Supply Current (Average)
Overpressure & Static Pressure Limits
- psi: 145 (kPa: 1,000, bar: 10) - Max.
Pressure Range
- kPa: -40 to 100
- mbar: -400 to 1,000
- psi: -05.8015 to 14.5
Storage Temperature
- -40° to 125° C (-40° to 257° F)
Update Time
- 35 milliseconds - Conversion Time