Specifications
Accuracy
- ± 2 % of Full Scale Reading - Non-Linearity
Output
- ± 2 Vdc - Full Scale Output Voltage
- 0.50-4.50 V (Output Voltage Swing)
- 2,500 ± 10 mV - Zero Acceleration Output
Sensitivity
- ± 0.25 % - Transverse Sensitivity
- 4-8 mV/g
- 6.45 mV/°C
Shock
- ± 4,000 G - Shock Survival
Supply Voltage
- ± 80 V - Input Voltage
- 8.5-36 V - Input Voltage - Operating
Temperature Range
- -40° to 85° C (-40° to 185° F)