8102 Plug & Play Accelerometer

Brand: American Sensor Technologies Inc

8102 Plug & Play Accelerometer

Brand: American Sensor Technologies Inc
The Model 8102 is a low cost, plug & play triaxial accelerometer. 

Featuring stable piezo-ceramic crystals, the accelerometer incorporates full power and signal conditioning with a maximum current consumption of only 22 micro-amps. 

The model 8102 is available from ±25 to ±6,000g ranges and provides a flat frequency response up to 6 kHz. The housing provides two holes for screw mounting and is offered in anodized Aluminum or Stainless Steel options.
Features
  • ±25 to ±6,000g Full Scale Ranges
  • Low Cost Triaxial
  • Potted Construction
  • Piezo-Ceramic Shear Design
  • -40° to 125°C (-40° to 257°F)
  • Integral Cable for Plug & Play

Specifications

Accuracy

  • ± 2 % of Full Scale Output - Non-Linearity

Applications

  • Asset Monitoring
  • Data Loggers
  • Impact Monitoring
  • Machine Health Monitoring
  • Product R & D
  • System Wake-Up Switch

Approvals & Certifications

  • CE
  • RoHS

Cable Material

  • ETFE Insulated

Consumption

  • < 22 µA

Current

  • < 22 µA - Total Supply

Electrical Connectors

  • 5 x 26 AWG Conductors ETFE Insulated
  • M3 Screws

Enclosure, Body Material

  • Aluminum - Anodized
  • Stainless Steel

Environmental Protection

  • IP65

Excitation Voltage

  • 3-5.5 Vdc

Frequency

  • > 10,000 to 30,000 Hz - Natural Frequency
  • 2 to 6,000 Hz at ± 2 dB

Insulation Resistance

  • > 100 megaohms at 100 Vdc

Load Impedance

  • < 100 ohms - Output Impedance

Mounting

  • M3 Screws
  • Surface Mounting - Ground Isolation

NACE & NIST

  • NIST - Traceable Amplitude Calibration

Operating Temperature

  • -40° to 125° C (-40° to 257° F)

Output Noise

  • 0.008 to 0.520 G RMS - Residual Noise
  • 0.07 to 32 mg√Hz at 10 Hz to 1 kHz - Spectral Noise

Seat / Seal Material

  • Epoxy Sealed - Humidity

Sensitivity

  • < 10 % - Transverse Sensitivity
  • 0.20 to 50 mV/g at ± 30 %

Shock

  • 5,000 to 10,000 G

Storage Temperature

  • -40° to 125° C (-40° to 257° F)

  • Asset Monitoring
  • Data Loggers
  • Impact Monitoring
  • Machine Health Monitoring
  • System Wake-Up Switch
  • Product R&D

show more