Accuracy
- ± 0.15 % of Span - Pressure Non-Linearity
Ambient Temperature Range
Approvals & Certifications
Compensated Temperature
- 0° to 50° C (32° to 122° F)
Humidity
- 0 to 85 % Relative Humidity
Hysteresis
- ± 0.25 % of Span - Pressure Hysteresis
Media
- Non-Corrosive Dry Gases Compatible with Silicon, Pyrex, RTV, Ceramic & Gold
Operating Temperature
- -25° to 85° C (-13° to 185° F)
Pressure Range
- psi: 0 to 300 (kPa: 0 to 2,068, bar: 0 to 20.68)
Resistance
- 3,500 to 6,500 ohms - Output Resistance
- 5,000 to 25,000 ohms - Input Resistance
Sensor, Probe Type
- Piezoresistive Silicon Sensor
Storage Temperature
- -40° to 125° C (-40° to 250° F)
Temperature Effect
- ± 0.75 mV - Temperature Error (Zero)
- ± 1 % of Span - Temperature Error - Span
Tube Connection
- 1/8” Barbed Ports Which Mate with 3/32” I.D. Tubing