XPM10 Miniature Pressure Transducer
Brand: American Sensor Technologies IncXPM10 Miniature Pressure Transducer
Brand: American Sensor Technologies IncThe XPM10 is a miniature transducer designed to measure static and dynamic pressure under a wide variety of conditions, including hostile environments.
It is made of stainless steel or titanium and is available in standard ranges from 0-1 to 350 bar (Up to 15 to 5,000 psi). APT1000 temperature probe is optionally available as a custom design. The XPM10 may integrate different electronics for amplified outputs A1: 0.5-4.5 V, A2: ±5 V, A3: 4-20 mA.
Features- Stainless Steel
- M10 x 1 Thread
- For Static and Dynamic Applications
- Low Installation Torque Sensitivity
Specifications
Approvals & Certifications
- CE
- EN 50081-1
- EN 50082-1
- EN 61010-1
Bandwidth
- 30 to 288 kHz - Resonnant Frequency
Compensated Temperature
- 0° to 60° C (32° to 140° F)
Consumption
- < 30 mA
Electrical Connectors
- M10 x 1 Thread
Environmental Protection
- IP50
- IP67
Hysteresis
- ± 0.25 % of Full Scale
Insulation Resistance
- ≥ 100 megaohms at 50 Vdc
Linearization
- ± 0.25 % of Full Scale
Materials of Construction
- 316 Stainless Steel
Media
- Fluids Compatible with Stainless Steel - Media (Pressure Port)
Non-Linearity
- ± 0.25 % of Full Scale at psi: 30
- ± 0.35 % of Full Scale at psi: 15
Operating Temperature
- -40° to 120° C (-40° to 248° F)
Power Requirement
- 10-30 Vdc
Pressure Range
- bar: 1 to 350
- kPa: 100 to 35,000
- psi: 15 to 5,000
Pressure Type
- Absolute
- Gauge
- Sealed Gauge
Repeatability
- ± 0.2 % of Full Scale
Resistance
- 500 to 1,500 ohms
Sensitivity
- ± 2 % of Reading at 50° C (122° F) - Thermal Sensitivity Shift in CTR
- 14 ± 0.4 mA Full Scale Output - Amplified A3
- 4 V ± 0.2 V Full Scale Output - Amplified A1
- 5 to 10 mV/V Full Scale Output - Non-Amplified
- 5 V ± 0.2 V Full Scale Output - Amplified A2
Version / Leadwires
- 2-Wire Circuit - Amplified A3 Version
Zero Balance
- ± 2 % of Full Scale at 50° C (122° F) ≥ 2 bar (psi: 30) - Thermal Zero Shift in CTR
- ± 3 % of Full Scale at 50° C (122° F) at 1 bar (psi: 15) - Thermal Zero Shift in CTR
Zero Offset
- < ± 1 mV/V - Non-Amplified
- 0 V ± 0.2 V - Amplified A2
- 0.5 V ± 0.2 V - Amplified A1
- 4 ± 0.4 mA - Amplified A3
- Hydraulic Regulation Process
- Explosion Test Benches
- Breaking System Pressure
- Laboratory and Research