FP110 Heavy Industrial Pressure Transducer

Brand: American Sensor Technologies Inc

FP110 Heavy Industrial Pressure Transducer

Brand: American Sensor Technologies Inc
The FP110 is designed to measure static and dynamic pressure with the output characteristics substantially kept up to about 20% of the resonant frequency. 

The all stainless steel construction and flush diaphragm allow the sensor to be used under a wide variety of conditions and in temperatures up to 120°C. For 200°C high temperature range model FP120-/HT. 

Fitted with metallic strain gauges in a Wheatstone bridge circuit, the FP110 provides excellent temperature stability. An onboard A1 or A2 amplifier for high level output is optionally available.
Features
  • Built in stainless Steel
  • M16 thread 
  • High Level Tension Output Available 
  • Accepts wide range of fluids 

Specifications

Accuracy

  • < ± 0.3 % of Full Scale
  • < ± 0.5 % of Full Scale

Applications

  • Corrosive Fluid Storage
  • Hydraulic Regulation Process
  • Industrial Pump Discharge
  • Laboratory & Research
  • On-Board Equipment Monitoring

Approvals & Certifications

  • CE
  • EN 50 082-1
  • EN 50081-1
  • EN 61010-1

Compensated Temperature

  • 0° to 60° C (32° to 140° F)

Diaphragm Material

  • Flush
  • Stainless Steel

Environmental Protection

  • IP66

Frequency

  • 15 to 55 kHz - Resonance Frequency

Hysteresis

  • ± 0.05 % of Span

Input Impedance

  • < 25 mA - FP110-A1, FP110-A2
  • 350 ohms - FP110

Insulation Resistance

  • ≥ 100 megaohms at 50 Vdc

Linearization

  • ± 0.3 % of Full Scale - Non-Linearity

Materials of Construction

  • 316 Stainless Steel

Operating Temperature

  • -40° to 80° C (-40° to 176° F)

Output

  • 1.2 mV/V - FP110
  • 4 V ± 0.2 V - FP110-A1
  • 5 V ± 0.2 V - FP110-A2

Pressure Range

  • bar: 10 to 500
  • kPa: 1,000 to 50,000
  • psi: 150 to 7,500

Pressure Type

  • Gauge

Sensitivity

  • < 1.5 % of Reading / 50° C (100° F) - Thermal Sensitivity Shift

Sensor, Probe Connection

  • 4-Wire

Supply Voltage

  • ± 15 Vdc (± 12 to ± 18 Vdc) - FP110-A2
  • 10 Vdc - FP110
  • 10-30 Vdc - FP110-A1

Thermal Drift

  • < 1 % of Full Scale / 50° C (100° F) - Thermal Zero Shift

Thread

  • M16

Wiring

  • Shielded Cable

Zero Offset

  • < ± 5 % of Full Scale - FP110
  • 0 V ± 0.2 V - FP110-A2
  • 0.5 V ± 0.2 V - FP110-A1

  • Industrial Pump Discharge 
  • Corrosive Fluid Storage 
  • Onboard Equipment Monitoring 
  • Hydraulic Regulation Process 
  • Laboratory and Research
show more