Accuracy
- Up to ± 0.1 % Pressure Non-Linearity
Ambient Temperature Range
Applications
- Fresh & Waste Water Measurements
- Medical Equipment
- Partial Vacuum Gas Measurement
- Pressure Transmitters
- Process Control
- Tank Level Systems (RV & Industrial)
Approvals & Certifications
Hysteresis
- ± 0.10 % of Span - Pressure Hysteresis
- ± 0.25 % of Span - Thermal Hysteresis: Span & Offset
Operating Temperature
- -40° to 125° C (-40° to 257° F)
Output
- ± 10 mV/V - Zero Pressure Output
- 1.5 mA - Supply Current
Output Noise
- 1 µV Peak-to-Peak - Output Noise (10 Hz to 1 kHz)
Pressure Range
- psi: 0 to 500 (kPa: 0 to 3,447, bar: 0 to 34.47)
Resistance
- 3,800 to 6,200 ohms - Bridge Resistance
Response Time
- 0.1 millisecond - Response Time (10 to 90 %)
Sensor, Probe Diameter
- 0.74” (19 mm) - Diameter Package
Stability
- ± 0.1 % of Span - Long Term Stability: Span
- ± 0.25 % of Span - Long Term Stability: Offset
Storage Temperature
- -50° to 125° C (-58° to 257° F)
Temperature Effect
- 1.30 to 3.50 Kppm/°C - Temperature Coefficient: Resistance