Ambient Temperature Range
Applications
- Fresh & Waste Water Measurements
- Medical Equipment
- Partial Vacuum Gas Measurement
- Pressure Transmitter
- Process Control
- Tank Level Systems (RV & Industrial)
Approvals & Certifications
Compensated Temperature
- -20° to 85° C (-4° to 185° F)
Hysteresis
- ± 0.05 % of Span - Pressure Hysteresis
- ± 0.25 % of Span - Thermal Hysteresis: Span & Offset
Linearization
- ± 0.2 % of Span - Pressure Non-Linearity
Media
- Liquids & Gases Compatible with 316L Stainless Steel
Operating Temperature
- -40° to 125° C (-40° to 257° F)
Output
- ± 1.0 mV - Zero Pressure Output
Pressure Range
- psi: 0 to 500 (kPa: 0 to 3,447, bar: 0 to 34.47)
Resistance
- 2,000 to 5,800 ohms - Input Resistance
- 4,000 to 6,000 ohms - Output Resistance
Stability
- ± 0.10 % of Span/Year - Long Term Stability (Span & Offset)
Storage Temperature
- -40° to 125° C (-40° to 250° F)