Accuracy
- ± 0.3 % Relative Humidity at 10 to 95 % Relative Humidity, Max.
- ± 0.5 % Relative Humidity at 10 to 95 % Relative Humidity, Max.
Approvals & Certifications
Humidity
- ± 2 % at 55 % Relative Humidity
- 0 to 100 % Relative Humidity
Hysteresis
- ± 1.5 % Relative Humidity - Humidity
Loop Resistance
- 10 kiloohms at 25° C - Nominal Resistance
Operating Temperature
- -40° to 85° C (-40° to 185° F)
Output
- 2.48 V at 55 % Relative Humidity at 5 Vdc - Nominal Output
Power Requirement
- 300 µA - Sink Current Capability
Sensitivity
- 26 mV/ % Relative Humidity - Average Sensitivity from 33 % to 75 % Relative Humidity
Stability
- ± 0.5 % Relative Humidity/Year
Storage Temperature
- -40° to 85° C (-40° to 185° F)
Temperature Effect
- 0.1 % Relative Humidity/°C
Temperature Range
- -40° to 85° C (-40° to 185° F)