Ambient Temperature Range
Approvals & Certifications
Burst Pressure
- psi: 1 to 30 (kPa: 6.895 to 206.8, bar: 0.0689 to 2.08)
Compensated Temperature
- -10° to 85° C (14° to 185° F)
Humidity
- 95 % Non-Condensing at 25° C (77° F)
Loop Resistance
- 10 kiloohms - Load Resistance
Operating Temperature
- -25° to 105° C (-13° to 221° F)
Overpressure & Static Pressure Limits
- psi: 60 (kPa: 413.7, bar: 4.137) at 25° C (77° F) of Both Ports - Overpressure
Pressure Range
- bar: 0.068 to 2.06
- kPa: 6.895 to 206.8
- psi: 1 to 30
Pressure Type
- Absolute
- Compound
- Differential
- Gauge
Shock
- MIL-STD-202F, Method 213B, Condition C, 3 Drops - Mechanical Shock
Storage Temperature
- -40° to 125° C (-40° to 257° F)
Vibration
- MIL-STD-202F, Method 214A, Condition 1 E, 1 Hr Each Axis - Mechanical Vibration
Wetted Materials
- Borosilicate Glass
- Copper Iron (CuFe)
- Epoxy Resin
- Gold - Port 1
- LCP
- RTV
- Silicone